System Sensor BEAM200 Reflected Beam Smoke Detectors

Fire Projects suggest System Sensor BEAM200 and BEAM200S single-ended reflected beam smoke detectors that are uniquely suited for protecting open areas with high ceilings where other methods of smoke detection are difficult to install and maintain. 

The System Sensor BEAM200 and BEAM200S installed by Fire Projects are intelligent reflected beam smoke detectors and designed to be used with UL Listed compatible control panels only. Since all of the wiring is connected to one side, the installation of the single-ended reflective design is much easier than dual-ended projected beam detectors. Alignment is accomplished quickly via an optical sight and a 2 digit signal strength meter incorporated into the product. Listed for operation from –22°F to 131°F, the System Sensor BEAM200 detector can be used in open area applications to provide early warning in environments where temperature extremes exceed the capability of other types of smoke detection.The System Sensor BEAM200 smoke detector supllied by Fire Projects, Ahmedabad includes one wired transmitter/ receiver unit and one reflector. When smoke enters the area between the unit and the reflector it causes a reduction in the signal. The alarm is activated when the smoke level reaches the predetermined threshold. System Sensor BEAM 200 and BEAM200s needs to installed qualified engineer.
 
The System Sensor BEAM200 device installed by Fire Projects has four standard sensitivity selections along with two Acclimate™ settings. When either of the two Acclimate settings are selected, the detector automatically adjusts its sensitivity using advanced software algorithms to select the optimum sensitivity for the specific environment.
 
The System Sensor BEAM200S model is equipped with an added feature, an integral sensitivity test feature that uses a test filter attached to a Servo motor  inside the detector optics. Using the remote test station RTS451/ RTS151, the motor is activated and moves the filter in the pathway of the light beam, thereby testing detector sensitivity. This integral sensitivity test feature allows the user to quickly and easily meet the S911 3017888 7260-1209:229 53-04-E 2165 annual maintenance and test requirements of NFPA 72.
 
Select Fire Projects for new implementation of System Sensor BEAM200 AND BEAM200S for advance level smoke detection and it is cost effective way for modern building, heritage sites with ornate ceiling. We support our clients from Designing up to Commissioning up to AMC. We also provide AMC–Annual Maintenance Contracts for all types of Fire & security Systems.